Maytag Dryer Error Codes
Maytag dryers share Whirlpool's control platform and show short codes when a cycle stops or won't heat. Find yours below with the meaning and first fix.
PF
Means: Power failure — the dryer detected a loss of power during a cycle.
Fix: Restart the cycle. If PF is frequent, check the outlet, the 240V breaker and the power cord for a loose contact.
AF
Means: Restricted airflow — exhaust airflow dropped below the sensing threshold.
Fix: Clean the lint screen and have the full duct measured; packed lint, a softener film on the mesh, or a crushed transition hose are typical causes.
L2
Means: Low voltage — the drum turns but the clothes stay wet.
Fix: Check the 240V breaker; a half-tripped leg or a burned outlet contact stops the heater while the motor still runs.
E1
Means: Open exhaust thermistor — the exhaust temperature circuit is open.
Fix: Check the thermistor wiring at the exhaust; replace the thermistor if the circuit reads open.
E2
Means: Shorted exhaust thermistor.
Fix: Replace the exhaust thermistor; a shorted sensor prevents the control from reading temperature.
F01
Means: Main control board failure.
Fix: Unplug the dryer for 5 minutes to clear a glitch. If F01 returns, replace the main control board.
FAQ
How do I reset a Maytag dryer?
Unplug the dryer or switch off its breaker for 5 minutes, then restore power. This clears PF and other temporary codes.
My Maytag dryer runs but won't heat — what code should I look for?
That's the classic L2 low-voltage symptom: the motor runs on one 240V leg but the heater needs both. Check for a half-tripped breaker before replacing any parts.